Unterschiede zwischen den Revisionen 3 und 4
Revision 3 vom 24.06.2014 16:10
Größe: 1783
Autor: HolgerB
Kommentar:
Revision 4 vom 24.06.2014 16:40
Größe: 2122
Autor: HolgerB
Kommentar:
Gelöschter Text ist auf diese Art markiert. Hinzugefügter Text ist auf diese Art markiert.
Zeile 5: Zeile 5:
Since KopterTool 1.06f, the version numbers are listed:
Zeile 6: Zeile 7:
{i} Instruction to '''update the BL V3''' here: [[en/BL_V3Update|Update]] {{http://gallery.mikrokopter.de/main.php?g2_view=core.DownloadItem&g2_itemId=153741&g2_serialNumber=1}}

 ./!\ if the version Number is 1.00 or, 1.02, the number is red and we strongly recommend to update!

 . {i} Instruction to '''update the BL V3''' here: [[en/BL_V3Update|Update]]
Zeile 13: Zeile 18:

/!\ we strongly recommend to update to version 1.04c or higher
Zeile 42: Zeile 45:
 * /!\ we strongly recommend to update to version 1.04c or higher
Zeile 46: Zeile 50:
 * /!\ we strongly recommend to update to version 1.04c or higher

Since KopterTool 1.06f, the version numbers are listed:

https://gallery.mikrokopter.de/main.php?g2_view=core.DownloadItem&g2_itemId=153741&g2_serialNumber=1

  • /!\ if the version Number is 1.00 or, 1.02, the number is red and we strongly recommend to update!
  • {i} Instruction to update the BL V3 here: Update

Firmware

Here you can find the latest versions vor the BL-Ctrl V3:

http://mikrocontroller.com/files/BL_V3

Version V1.06b

since 20th June 2014

  • Redundance operation: some small bugfixes in communication
  • "ERR:Motor restart" at high current peaks the message "ERR:Motor Restart" could occure instead of "BL-Limitation"

  • some motors lost commutation when driving at high currents
    • then comes the message "BL-Limitation" or "ERR:Motor Restart"

    • Timing 28° was improved for the case of commutation loss

Version V1.04c

since 07th May 2014

Download: V1.04c

http://gallery.mikrokopter.de/main.php/v/tech/Versionskennung.jpg.html

  • better protection against high current peaks during operation
  • Safer behavior while operation without propellers
  • Integrated watchdog that restarts the BL controllers in case of a failure
  • Various bug fixes

Version V1.02d

Since 17th March 2014

  • Improved motor-start by a self-learning start phase
  • internal speed limitation
  • increased commutating speed (Max RPM is 200.000 devided by the number of magnets -> 16.666 RPM if you have 12magnets)

  • Prepared for redundant FC-Operation
  • /!\ we strongly recommend to update to version 1.04c or higher

Version V1.00f

Since 1st Jan. 2014

  • First Version
  • /!\ we strongly recommend to update to version 1.04c or higher

/!\ we strongly recommend to update to version 1.04c or higher!