Parameters
Explanation of the different user configurable parameters
Parameter |
Low |
High |
Nick / Roll P-Anteil |
Spongy control |
Strong reaction to control stick movements, high agility. |
Nick / Rol D-Anteil |
Slow but soft control |
Strong model reactions to fast stick movements |
Gier P-Anteil |
Slow reactions |
Fast reactions |
Gyro P-Anteil |
Unflyable if too low !!! |
Fast response, can be set until just under "wagging" |
Gyro I-Anteil |
Weak response, oscillates, very sensitive to wind |
Hard response (high angular stability), can be set until just under "wagging" |
Hauptregler I-Anteil |
|
"Heading hold". Similar to Gyro-I-Anteil. |
Standard Parameter sets in v.0.68d.
Parameter |
Set 1 Sport |
Set 2 Normal |
Set 3 Beginner |
|
|
|
|
Stick |
|
|
|
Nick/Roll P-Anteil |
4 |
3 |
3 |
Nick/Roll D-Anteil |
8 |
4 |
4 |
Gier P-Anteil |
12 |
6 |
6 |
Gyro Werte |
|
|
|
Gyro P-Anteil |
80 |
80 |
100 |
Gyro I-Anteil |
150 |
120 |
140 |
Dyn. Stability |
100 |
75 |
50 |
ACC/Gyro Faktor |
30 |
30 |
30 |
ACC/Gyro Comp. |
16 |
32 |
32 |
Hauptregler I Anteil |
32 |
32 |
16 |
Drift Compensation |
4 |
4 |
4 |
Höhenregelung |
|
|
|
Sollhöhe |
Poti 1 (od. Wert eintr.) |
Poti 1 (od. Wert eintr.) |
Poti 1 (od. Wert eintr.) |
Min.Gas |
30 |
30 |
30 |
Höhe P-Anteil |
10 |
10 |
10 |
Luftdruck D-Anteil |
30 |
30 |
30 |
Z-ACC Wirkung |
30 |
30 |
30 |
Verstärkung |
4 |
3 |
2 |
Achsenkopplung |
|
|
|
Gier/Yaw pos.feedback |
90 |
90 |
90 |
Gier/Yaw neg. feedback |
5 |
5 |
5 |
Loop |
|
|
|
Gas Limit |
50 |
50 |
50 |
Ansprechschwelle |
90 |
90 |
90 |
Turn Over Nick |
100 |
100 |
100 |
Turn Over Roll |
100 |
100 |
100 |
Hysteresis |
50 |
50 |
50 |
Sonstiges |
|
|
|
Min. Gas |
15 |
15 |
15 |
Max. Gas |
250 |
250 |
250 |
Kompasswirkung |
128 |
128 |
128 |
Unterspannung |
96 |
96 |
96 |
Not Gas Zeit (0,1 sec.) |
20 |
20 |
20 |
Not Gas |
35 |
35 |
35 |
Kamera |
|
|
|
Servo Control |
100 |
100 |
100 |
Nick Copmensation |
40 |
40 |
40 |
Servo Min. |
50 |
50 |
50 |
Servo Max. |
150 |
150 |
150 |
Servo Refresh Rate |
5 |
5 |
5 |
Undervoltage / Unterspannung
Make sure, you select the correct value for your LiPo.
Recommended: 3,2V/cell (3s = 96 ; 4s=128)
Other Parameter sets that work well for RC AP with different motors and props
Please add your parameters sets which have worked well here. Include description of motors, props. and RTF weight !! ToDo: hier gibt es noch etwas zu tun
- (Hier kann ein Link auf eine Kategorie eingefügt werden)